Guides are only intended for use on Atwood™ products by service technicians who have successfully completed Atwood™ training. This guide should be used in conjunction with the appropriate Instruction Manual provided with the product and any applicable Industry Standards. This is not intended to be a complete list. Please direct questions concerning service of Atwood™ products to 815-877-5700 or service@atwoodmobile.com

Warning Image

BURNER FAILS TO IGNITE AND BLOWER FAILS TO RUN


CONDITION

     SOLUTION

  • No electrical power to the furnace
  • Thermostat defective
  • Thermostat wires broken or shorted
  • Current overload protector device defective or
       tripped (circuit breaker)
  • Blower relay defective
  • Wire off motor
  • Wire off relay
  • Improper ground
  • Blower motor defective
    • Reconnect or replace power source*
    • Replace thermostat
    • Replace wire or wires*
    • Reset circuit breaker
      Check amp draw from motor according to furnace's specification
    • Replace relay
    • Reconnect wire
    • Reconnect wire
    • Clean and secure grounds*
    • Replace motor

    BLOWER RUNS BUT FAILS TO IGNITE


    CONDITION

         SOLUTION

  • Low voltage
  • Gas pressure incorrect


  • Furnace grounding wires not secure
  • Air intake restricted
  • 12 volt polarity reversed
  • Motor running slow

  • Exhaust blocked
  • Combustion air wheel loose
  • Sail switch defective or wire off
  • Limit switch defective or off wire
  • Edge connector on cicuit board dirty
  • Circuit board defective

  • Gas valve defective

  • Main burner orifice blocked
  • High tension lead wire defective
  • Electrode out of adjustment
  • Electrode defective
  • Obstructed burner head
    • Correct Power Supply*
    • Set pressure to a minimum of 11"W.C. with all appliances running. (Replace regulator if not obtainable).*
    • Clean and secure grounds established*
    • Clean air intake*
    • Correct polarity*
    • Check voltage first
      If 12 VDC while running, replace motor
    • Clean exhaust*
    • Reposition and tighten
    • Reconnect wire or replace
    • Reconnect wire or replace
    • Clean with pencil eraser
    • Clean plug contacts. If still defective, replace. (check on board tester when possible).
    • Replace valve or valve coil, depending on problem encountered
    • Clean main burner orifice or replace
    • Replace wire
    • Adjust electrode (take care not to damage porcelain)
    • Replace
    • Clean burner head*

    BURNER IGNITES BUT IGNITION SYSTEM "LOCKS OUT" AND TURNS BURNER OFF


    CONDITION

         SOLUTION

  • Low gas pressure


  • Exhuast blocked
  • Combustion air wheel loose
  • Electrodes out of adjustment
  • Electrode defective
  • Circuit board defective

  • Flame sensor wire between electrode and
       circuit board defective
  • Air leakage at gaskets
  • Defective heat exchanger
    • Set pressure to a minimum of 11"W.C. with all appliances running. Replace regulator if not obtainable.*
    • Clean Exhaust*
    • Reposition wheel and tighten
    • Adjust electrode according to furnace specifications
    • Replace electrode
    • Clean plug contacts. If still defective, replace. (Check on board tester when possible).
    • Replace wire

    • Replace gasket
    • Replace heat exchanger

    SOOTING (caused by lazy yellow flame)


    CONDITION

         SOLUTION

  • Low gas pressure


  • Low voltage
  • Air leakage at gaskets
  • Combustion wheel installed backwards
  • Blockage in heating chamber or burner head
  • Faulty motor
    • *Set pressure to a minimum of 11"W.C. with all appliances running. Replace regulator if not obtainable
    • Correct power supply*
    • Replace gaskets
    • Reposition wheel and tighten
    • Clean or replace
    • Replace motor

    FAN RUNS CONTINOUSLY WITH THERMOSTAT "OFF"


    CONDITION

         SOLUTION

  • Defective thermostat
  • Shorted thermostat leads
  • Defective relay
    • Replace thermostat
    • *Replace wire or wires.
    • Replace relay

    LIMITING = BURNER CYCLING ON AND OFF
       BLOWER RUNS CONSTANTLY WITH THERMOSTAT ON


    CONDITION

         SOLUTION

  • Furnace over fired



  • Restricted return air supply

  • Restricted or insufficient discharge ducting




  • Defective limit switch
    • Set gas pressure to a minimum of 11"W.C. with all appliances running. Replace regulator if not obtainable. Also, check main burner orifice, it must comply with furnace's specifications.*
    • Make sure return air meets furnace's minimum requirements.*
      • a. Ducting must meet furnace's minimum requirements*
        b. No excess ducting or unnecessary bends*
        c. All closeable registers must be fully open and unrestricted*
    • Replace limit switch

    BLOWER SHUTS OFF AT SAME TIME BURNER SHUTS OFF


    CONDITION

         SOLUTION

  • Wired wrong
  • Faulty relay
    • Correct wiring*
    • Replace relay

    BLOWER VIBRATES OR IS NOISY


    CONDITION

         SOLUTION

  • Motor mount loose




  • Damaged blower wheel
  • Motor shaft bent
    • Tighten motor mounting bracket
        a. Ducting must meet furnace's minimum requirements* b. No excess ducting or unecessary bends* c. All closable registers must be fully open and unrestricted
    • Replace blower wheel
    • Replace blower motor

    INSUFFICIENT HEAT


    CONDITION

         SOLUTION

  • Furnace under fired
    • 1. Set gas pressure to 11"W.C. with all appliances running. Replace regulator if not obtainable. Also, check main burner orifice, it must comply with furnace's specifications*
    • 2. Check ducting and return air according to furnaces specifications*

    * not covered under warranty